15-00043
Revision 3
September 2005
The publication, translation or reproduction, either party or wholly, of this document are not allowed without our written consent. 13
Figure 4 below depicts the configuration of the front panel:
Figure 4 – Front Panel
Figure 5 below depicts the back panel of the base with one or two RPSMA connectors to connect
the antennas.
Figure 5 – Antenna Panel
As soon as the power is turned ON, any RF data received by the radio is converted to RS-232
format and sent to the serial port (DB-9 connector if used) and the network adapter (RJ-45
connector if used) simultaneously. This means that the base can be connected to the network for
the TeleView 2000 Software (Telecast Server) or other similar program to read the TCP/IP
transmission from the network adaptor, and at the same time, a PC can be connected to the RS-232
port for local monitoring. Any RS-232 data from the host computer will be transmitted to all
remote units or repeaters within range.
Data to the serial port and network adapter is sent at by default at 19,200 BAUD, Parity NONE, 8
Data Bits, and 1 Stop Bit. All data is ASCII formatted, permitting use of any terminal program for
inspection/troubleshooting.