15-00044
Revision 5
April 2008
The publication, translation or reproduction, either party or wholly, of this document are not allowed without our written consent. 28
5. Communication
5.1 Communication
The communication between the DRM and PC can be performed in 3 ways:
1) Wireless Radio WRM2 located inside the meter.
2) Direct RS232 via the meter communication port (D-type 9 pin female connector using a Null
Modem Adaptor).
3) WRM External Transmitter can be connected to the D-type 9 pin female connector via the AMP
to WRM adapter.
5
.2 Protocol
Communication parameters:
• Baud rate: can be selected between 300, 4800, 9600 and 19200 is the default.
• Parity: None
• Hardware handshaking: None
• Software handshaking: None
• Stop bit: 1
• Prefix: LF
• Suffix: CR
• Data format: 8 data bits
6. Communication Protocol
Description: DRM data to PC via radio or RS232
Byte 1 LF
Byte 2 to byte 7 Id meter number for communication set via Meter View software
Byte 8 status = 0x30=okay, 0x31=over load, 0x32=over threshold, 0x33=no external power, 0x34=low backup
battery, 0x38=detector fault.
Byte 9 Status = multiple status messages – See information below.
Byte 10 to byte 16 Dose Reading (x.xxxxx) or 8.88888 in case the Dose is disabled
Byte 17 = 0x30
Byte 18 to byte 22 rate reading X.YZW * 10
T
Byte 23 = 0x30
Byte 24 to byte 25 check sum
Byte 26 CR